Fracture of the Neck of a Modern Cementless, Titanium Femoral Stem
Intraprosthetic fracture of a femoral component is a rare but devastating complication after total hip arthroplasty (THA). We present the case of a 68-year-old man who presented with acute hip pain approximately 8 years after a left THA with a modern cementless, titanium femoral component. Radiograp...