Overcoming sheaths overlapping in a small diameter metallic tube with one end closed and using a high density plasma from a high power pulsed hollow cathode discharge

High voltage sheaths are formed when plasmas are produced by application of high negative voltage pulses to conductive supports or components, as in Plasma Immersion Ion Implantation (PIII) treatments of materials surfaces. For parts with concave shape, as inside metal tubes, these sheaths behave qu...

Full description

Bibliographic Details
Main Authors: M. Ueda, C. Silva, G. B. de Souza, S. F. M. Mariano, L. Pichon
Format: Article
Language:English
Published: AIP Publishing LLC 2018-08-01
Series:AIP Advances
Online Access:http://dx.doi.org/10.1063/1.5040588
_version_ 1831805320787132416
author M. Ueda
C. Silva
G. B. de Souza
S. F. M. Mariano
L. Pichon
author_facet M. Ueda
C. Silva
G. B. de Souza
S. F. M. Mariano
L. Pichon
author_sort M. Ueda
collection DOAJ
description High voltage sheaths are formed when plasmas are produced by application of high negative voltage pulses to conductive supports or components, as in Plasma Immersion Ion Implantation (PIII) treatments of materials surfaces. For parts with concave shape, as inside metal tubes, these sheaths behave quite differently according to the tube configuration and size, as well as, PIII treatment pressure of operation and pulsing parameters. In this work, an SS304 tube of 1.1 cm internal diameter and 20 cm length was pulsed typically at -0.5 to -2.6 kV, 20 μs pulse length, 500 Hz repetition rate, nitrogen pressure of 5x10-2 mbar and with one side closed configuration. Different currents (between 10 and 30 A) were used to produce plasmas with sheaths that overlapped or not, depending on the currents used. To study these sheath behaviors, a simple plasma diagnostic technique based on a bi-dimensional mapping of the deposition of sputtered materials and by etching via the plasma on a Si wafer target surface, both coming out from the tube, was used. This mapping showed clearly the border line situation between overlapping and non-overlapping sheaths in that small tube which allowed to estimate the plasma density to be around 1011 cm-3 at such a sheath condition, as previously anticipated by Sheridan. Above that border condition, nitrogen PIII was successfully obtained in such a small tube of SS304, producing TiN and Ti2N in samples of Ti6Al4V placed inside the tube, when temperatures higher than 800°C were reached there. Below the border, no significant uptake of nitrogen was possible. Using this type of experimental set-up, it is now possible to explore different hollow cathode behaviors, efficient or high temperature (above 800°C) PIII conditions and also new utilizations of the plasma ejected from the tube.
first_indexed 2024-12-22T19:22:05Z
format Article
id doaj.art-1ee4076b87664d92b04e0cf32efc89c4
institution Directory Open Access Journal
issn 2158-3226
language English
last_indexed 2024-12-22T19:22:05Z
publishDate 2018-08-01
publisher AIP Publishing LLC
record_format Article
series AIP Advances
spelling doaj.art-1ee4076b87664d92b04e0cf32efc89c42022-12-21T18:15:21ZengAIP Publishing LLCAIP Advances2158-32262018-08-0188085103085103-1310.1063/1.5040588123807ADVOvercoming sheaths overlapping in a small diameter metallic tube with one end closed and using a high density plasma from a high power pulsed hollow cathode dischargeM. Ueda0C. Silva1G. B. de Souza2S. F. M. Mariano3L. Pichon4Associated Laboratory of Plasmas - LABAP, National Institute for Space Research-INPE, São José dos Campos, SP 12227-010, BrazilAssociated Laboratory of Plasmas - LABAP, National Institute for Space Research-INPE, São José dos Campos, SP 12227-010, BrazilState University of Ponta Grossa, PR 84030-000, BrazilAssociated Laboratory of Plasmas - LABAP, National Institute for Space Research-INPE, São José dos Campos, SP 12227-010, BrazilInstitut Pprime - CNRS -Université de Poitiers-ENSMA, Poitiers UPR 3346, FranceHigh voltage sheaths are formed when plasmas are produced by application of high negative voltage pulses to conductive supports or components, as in Plasma Immersion Ion Implantation (PIII) treatments of materials surfaces. For parts with concave shape, as inside metal tubes, these sheaths behave quite differently according to the tube configuration and size, as well as, PIII treatment pressure of operation and pulsing parameters. In this work, an SS304 tube of 1.1 cm internal diameter and 20 cm length was pulsed typically at -0.5 to -2.6 kV, 20 μs pulse length, 500 Hz repetition rate, nitrogen pressure of 5x10-2 mbar and with one side closed configuration. Different currents (between 10 and 30 A) were used to produce plasmas with sheaths that overlapped or not, depending on the currents used. To study these sheath behaviors, a simple plasma diagnostic technique based on a bi-dimensional mapping of the deposition of sputtered materials and by etching via the plasma on a Si wafer target surface, both coming out from the tube, was used. This mapping showed clearly the border line situation between overlapping and non-overlapping sheaths in that small tube which allowed to estimate the plasma density to be around 1011 cm-3 at such a sheath condition, as previously anticipated by Sheridan. Above that border condition, nitrogen PIII was successfully obtained in such a small tube of SS304, producing TiN and Ti2N in samples of Ti6Al4V placed inside the tube, when temperatures higher than 800°C were reached there. Below the border, no significant uptake of nitrogen was possible. Using this type of experimental set-up, it is now possible to explore different hollow cathode behaviors, efficient or high temperature (above 800°C) PIII conditions and also new utilizations of the plasma ejected from the tube.http://dx.doi.org/10.1063/1.5040588
spellingShingle M. Ueda
C. Silva
G. B. de Souza
S. F. M. Mariano
L. Pichon
Overcoming sheaths overlapping in a small diameter metallic tube with one end closed and using a high density plasma from a high power pulsed hollow cathode discharge
AIP Advances
title Overcoming sheaths overlapping in a small diameter metallic tube with one end closed and using a high density plasma from a high power pulsed hollow cathode discharge
title_full Overcoming sheaths overlapping in a small diameter metallic tube with one end closed and using a high density plasma from a high power pulsed hollow cathode discharge
title_fullStr Overcoming sheaths overlapping in a small diameter metallic tube with one end closed and using a high density plasma from a high power pulsed hollow cathode discharge
title_full_unstemmed Overcoming sheaths overlapping in a small diameter metallic tube with one end closed and using a high density plasma from a high power pulsed hollow cathode discharge
title_short Overcoming sheaths overlapping in a small diameter metallic tube with one end closed and using a high density plasma from a high power pulsed hollow cathode discharge
title_sort overcoming sheaths overlapping in a small diameter metallic tube with one end closed and using a high density plasma from a high power pulsed hollow cathode discharge
url http://dx.doi.org/10.1063/1.5040588
work_keys_str_mv AT mueda overcomingsheathsoverlappinginasmalldiametermetallictubewithoneendclosedandusingahighdensityplasmafromahighpowerpulsedhollowcathodedischarge
AT csilva overcomingsheathsoverlappinginasmalldiametermetallictubewithoneendclosedandusingahighdensityplasmafromahighpowerpulsedhollowcathodedischarge
AT gbdesouza overcomingsheathsoverlappinginasmalldiametermetallictubewithoneendclosedandusingahighdensityplasmafromahighpowerpulsedhollowcathodedischarge
AT sfmmariano overcomingsheathsoverlappinginasmalldiametermetallictubewithoneendclosedandusingahighdensityplasmafromahighpowerpulsedhollowcathodedischarge
AT lpichon overcomingsheathsoverlappinginasmalldiametermetallictubewithoneendclosedandusingahighdensityplasmafromahighpowerpulsedhollowcathodedischarge