Biomechanical Analysis of Single Interference Screw vs Interference Screw With Cortical Button for Flexor Hallucis Longus Transfer
Background: Flexor hallucis longus tendon transfer (FHL) with a cortical button tension slide is an innovative addition that has not been measured against traditional methods. Methods: 12 pairs (n=24) of fresh-frozen cadaveric tibia-to-toe samples were used and randomized to receive one of the opera...
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
SAGE Publishing
2021-10-01
|
Series: | Foot & Ankle Orthopaedics |
Online Access: | https://doi.org/10.1177/24730114211040445 |