Field analysis & eddy current losses calculation in five-phase tubular actuator
Field analysis including eddy currents in the magnetic core of five-phase permanent magnet tubular linear actuator (TLA) has been carried out. The eddy currents induced in the magnetic core cause the losses which have been calculated. The results from 2D finite element (FE) analysis have been compar...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
De Gruyter
2017-12-01
|
Series: | Open Physics |
Subjects: | |
Online Access: | https://doi.org/10.1515/phys-2017-0107 |