Control of the corrosion in sewage systems for Bohai oilfield

According to the analysis of the corrosion products from the Bohai oilfield sewage system,the main causes of corrosion were the high concentration of ferric ion and amide chemicals in the sewage. Among those causes, the under-deposit corrosion caused by a large amount of iron scale was the most impo...

Full description

Bibliographic Details
Main Authors: XUE Rui, GUO Baili, XU Hui, WU Tao
Format: Article
Language:zho
Published: Editorial Office of Industrial Water Treatment 2024-08-01
Series:Gongye shui chuli