Mitigation of high-resistance connection in surface-mounted PMSM drive system based on model predictive current control
High-resistance connection fault can result in the increasing of power loss and the rise of heat, so the electric machine drive system possibly can be damaged. Therefore, to reduce the copper loss caused by high-resistance connection in surface mounted permanent magnet synchronous machine drive syst...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier
2022-09-01
|
Series: | Results in Engineering |
Subjects: | |
Online Access: | http://www.sciencedirect.com/science/article/pii/S2590123022002602 |