Case Report: Iatrogenic trauma of the bladder due to long-term unidentified intrauterine device malposition inside the bladder with rectovesical fistula [version 2; peer review: 2 approved]
According to reports, there are 1.9–3.6 incidences of IUD migration and uterine perforation for every 1000 IUD insertions. It is important to note that bladder perforation caused by a misplaced IUD is uncommon and is thought to happen most frequently during insertion. Here, we describe a patient who...