Module level EMC verification method for replacement items in nuclear power plant

Internal replaceable electronic module substitutions can impact EMC (ElectroMagnetic Compatibility) qualification testing and results if EMC testing is conducted at the cabinet level. The impact of component substitutions on EMC qualification results therefore should be evaluated. If a qualitative e...

Full description

Bibliographic Details
Main Authors: Hee-Taek Lim, Moon-Gi Min, Hyun-Ki Kim, Gwang-Hyun Lee, Chae-Hyun Yang
Format: Article
Language:English
Published: Elsevier 2023-07-01
Series:Nuclear Engineering and Technology
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S1738573323001213