Management of the displaced transverse fracture patella by a new technique of transosseous fixation with endobuttons
Background: Although tension-band wiring is the most widely used technique to treat patellar fractures, metal implant-related complications such as implant failure, palpable hardware are very common and additional procedures are often necessary to treat the complications. We are presenting a new tec...