The discontinuity required at an air valve or vent for effective pipeline de-aeration
The location and sizing of air valves to ensure effective de-aeration of pipelines and to provide vacuum break capability was researched. Based on these findings, software was developed to evaluate gravity and pumping systems. A sound understanding of the factors affecting the hydraulic transportati...