Quenching distance of laminar methane-air flames at cryogenic temperatures and implications for flame arrester design
Understanding flame quenching is needed to develop efficient flame arresters. Here, the quenching distance of methane-air laminar flames is measured at atmospheric pressure for temperatures of the quenching surface down to the cryogenic, Tw = 138 K to 293 K, for two configurations: head-on and tube...
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier
2020-12-01
|
Series: | Applications in Energy and Combustion Science |
Subjects: | |