DUSTY ENVIRONMENT IMPACT ON LIFESPAN OF THE INDUCTION MOTORS STATOR WINDING
Large quantity of asynchronous motors work in heavily dusted environments. On the end-winding insulation of the motors to 55 kW operating in the mining and smelting enterprise there is a 3 cm dust layer, which may lead to the asynchronous motor end-winding local overheat and consequent early breakdo...
Main Authors: | , |
---|---|
Format: | Article |
Language: | Russian |
Published: |
Belarusian National Technical University
2015-12-01
|
Series: | Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика |
Subjects: | |
Online Access: | https://energy.bntu.by/jour/article/view/896 |