Uniaxial Tension of a Filament-wound Composite Tube at Low Temperature
The aim of this article is to model mechanical behavior of a filament-wound, rubber-based composite tube subjected to uniaxial tension at low temperature by test experiments and FE simulations. Uniaxial tensile tests at sub-zero temperature (-40 °C) have been carried out on standard test specimens a...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Széchenyi István University
2018-07-01
|
Series: | Acta Technica Jaurinensis |
Subjects: | |
Online Access: | https://acta.sze.hu/index.php/acta/article/view/456 |