Failure Analysis of a Centrifugal Compressor Impeller Made of 17-4PH Steel in the Moist Hydrogen Sulfide Environment
The impeller under consideration is a rotor wheel of a centrifugal compressor, made of 17-4PH martensitic precipitated hardening stainless steel. Its total operating lifetime was estimated to 80,000 h, but it fractured beforehand, 4 days after the scheduled overhaul without any observed pre-symptoms...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2022-06-01
|
Series: | Energies |
Subjects: | |