An evaluation method of observable charge trap depth for the pea method and its complementarity with the Q(t) method

This paper proposes an evaluation method for the observable trap depth range of space charge when using the pulsed electro-acoustic (PEA) method and its complementarity with the current integration charge (Q(t)) method. Based on the measurement process of the PEA method and the hopping conduction pr...

Full description

Bibliographic Details
Main Authors: Hanwen Ren, Tatsuo Takada, Yasuhiro Tanaka, Qingmin Li
Format: Article
Language:English
Published: Polish Academy of Sciences 2021-09-01