Quantification of Cr in Natural Sparkling Mineral Waters by Inductively Coupled Plasma-Mass Spectrometry

Natural sparkling mineral water contains high concentrations of HCO3- (about 1500 mg/L) and CO2(about 400 mg/L) and the concentration of Cr is equal to or lower than the detection limit of Inductively Coupled Plasma-Atomic Emission Spectrometry (ICP-AES). Moreover, it is easy to form the polyatomic...

Full description

Bibliographic Details
Main Authors: ZHANG Bao-ke, WANG Lei, MA Sheng-feng
Format: Article
Language:English
Published: Science Press, PR China 2013-07-01
Series:Yankuang ceshi
Subjects:
Online Access:http://www.ykcs.ac.cn/en/article/id/f4ece52c-7679-4883-a2ff-e57adb9b0536
_version_ 1811167427585638400
author ZHANG Bao-ke
WANG Lei
MA Sheng-feng
author_facet ZHANG Bao-ke
WANG Lei
MA Sheng-feng
author_sort ZHANG Bao-ke
collection DOAJ
description Natural sparkling mineral water contains high concentrations of HCO3- (about 1500 mg/L) and CO2(about 400 mg/L) and the concentration of Cr is equal to or lower than the detection limit of Inductively Coupled Plasma-Atomic Emission Spectrometry (ICP-AES). Moreover, it is easy to form the polyatomic ion 40Ar12C, which interferes with the determination of 52Cr in the water by Inductively Coupled Plasma-Mass Spectrometry (ICP-MS). Therefore, it is not possible to accurately quantify Cr in natural sparkling mineral water by ICP-MS. In this paper, a new method is described to quantify Cr in natural sparkling mineral water. The water is heated to 100℃ for 2 minutes, cooled to room temperature, and the acidity of the samples is adjusted to 5% (volume ratio) with nitric acid,which promotes HCO3- and H+ reactions to generate CO2 gas, thus being rapidly released. The interference of 40Ar12C on 52Cr is eliminated by this pretreatment of the natural sparkling mineral water, and the accurate determination of Cr in the water was conducted by ICP-MS. The detection limit of this method is 0.23 ng/mL. The results were satisfactory with the recoveries from 92.3% to 93.7%. This method is not only simple and practical, but can also be used to simultaneously and accurately quantify Ni, Cu, As, Cd and Pb in the water samples by ICP-MS. Its precision and accuracy meet the requirements of natural mineral water analysis.
first_indexed 2024-04-10T16:10:16Z
format Article
id doaj.art-3fbc9f2bf26642c4b2ce17bbe5982881
institution Directory Open Access Journal
issn 0254-5357
language English
last_indexed 2024-04-10T16:10:16Z
publishDate 2013-07-01
publisher Science Press, PR China
record_format Article
series Yankuang ceshi
spelling doaj.art-3fbc9f2bf26642c4b2ce17bbe59828812023-02-10T01:31:34ZengScience Press, PR ChinaYankuang ceshi0254-53572013-07-01324568571ykcs-32-4-568Quantification of Cr in Natural Sparkling Mineral Waters by Inductively Coupled Plasma-Mass SpectrometryZHANG Bao-ke0WANG Lei1MA Sheng-feng2National Research Center for Geoanalysis, Beijing 100037, ChinaNational Research Center for Geoanalysis, Beijing 100037, ChinaNational Research Center for Geoanalysis, Beijing 100037, ChinaNatural sparkling mineral water contains high concentrations of HCO3- (about 1500 mg/L) and CO2(about 400 mg/L) and the concentration of Cr is equal to or lower than the detection limit of Inductively Coupled Plasma-Atomic Emission Spectrometry (ICP-AES). Moreover, it is easy to form the polyatomic ion 40Ar12C, which interferes with the determination of 52Cr in the water by Inductively Coupled Plasma-Mass Spectrometry (ICP-MS). Therefore, it is not possible to accurately quantify Cr in natural sparkling mineral water by ICP-MS. In this paper, a new method is described to quantify Cr in natural sparkling mineral water. The water is heated to 100℃ for 2 minutes, cooled to room temperature, and the acidity of the samples is adjusted to 5% (volume ratio) with nitric acid,which promotes HCO3- and H+ reactions to generate CO2 gas, thus being rapidly released. The interference of 40Ar12C on 52Cr is eliminated by this pretreatment of the natural sparkling mineral water, and the accurate determination of Cr in the water was conducted by ICP-MS. The detection limit of this method is 0.23 ng/mL. The results were satisfactory with the recoveries from 92.3% to 93.7%. This method is not only simple and practical, but can also be used to simultaneously and accurately quantify Ni, Cu, As, Cd and Pb in the water samples by ICP-MS. Its precision and accuracy meet the requirements of natural mineral water analysis.http://www.ykcs.ac.cn/en/article/id/f4ece52c-7679-4883-a2ff-e57adb9b0536natural sparkling mineral waterscrinductively coupled plasma-mass spectrometry40arc
spellingShingle ZHANG Bao-ke
WANG Lei
MA Sheng-feng
Quantification of Cr in Natural Sparkling Mineral Waters by Inductively Coupled Plasma-Mass Spectrometry
Yankuang ceshi
natural sparkling mineral waters
cr
inductively coupled plasma-mass spectrometry
40arc
title Quantification of Cr in Natural Sparkling Mineral Waters by Inductively Coupled Plasma-Mass Spectrometry
title_full Quantification of Cr in Natural Sparkling Mineral Waters by Inductively Coupled Plasma-Mass Spectrometry
title_fullStr Quantification of Cr in Natural Sparkling Mineral Waters by Inductively Coupled Plasma-Mass Spectrometry
title_full_unstemmed Quantification of Cr in Natural Sparkling Mineral Waters by Inductively Coupled Plasma-Mass Spectrometry
title_short Quantification of Cr in Natural Sparkling Mineral Waters by Inductively Coupled Plasma-Mass Spectrometry
title_sort quantification of cr in natural sparkling mineral waters by inductively coupled plasma mass spectrometry
topic natural sparkling mineral waters
cr
inductively coupled plasma-mass spectrometry
40arc
url http://www.ykcs.ac.cn/en/article/id/f4ece52c-7679-4883-a2ff-e57adb9b0536
work_keys_str_mv AT zhangbaoke quantificationofcrinnaturalsparklingmineralwatersbyinductivelycoupledplasmamassspectrometry
AT wanglei quantificationofcrinnaturalsparklingmineralwatersbyinductivelycoupledplasmamassspectrometry
AT mashengfeng quantificationofcrinnaturalsparklingmineralwatersbyinductivelycoupledplasmamassspectrometry