Comparison of the Flow Field in a Slab Continuous Casting Mold between the Thicknesses of 180 mm and 250 mm by High Temperature Quantitative Measurement and Numerical Simulation
In the present work, the flow field in a slab continuous casting mold with thicknesses of 180 and 250 mm are compared using high temperature quantitative measurement and numerical simulation. The results of the numerical simulation are in agreement with those of the high temperature quantitative mea...