Case report: Endoluminal removal of a retrievable conical inferior vena cava filter with a ruptured retraction hook attached to the wall
We report the case of a patient who underwent endovascular retrieval of a conical inferior vena cava (IVC) filter with a ruptured retraction hook that was attached to the IVC wall. A 21-year-old woman with a Celect (Cook) filter, implanted 1,522 days prior, requested retrieval. Preoperative ultrasou...