Study of reactor plant disturbed cooling condition modes caused by the VVER reactor secondary circuit
Based on the equations of energy, mass and momentum conservation for the three-dimensional unsteady flow of the two-phase mixture, simulations were made of reactor plant disturbed cooling condition modes caused by the VVER secondary circuit using computer thermohydraulic codes. The use of computer c...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
National Research Nuclear University (MEPhI)
2016-12-01
|
Series: | Nuclear Energy and Technology |
Subjects: | |
Online Access: | http://www.sciencedirect.com/science/article/pii/S245230381630108X |