Thermo-Mechanical Fatigue (TMF) Model for (2017-T4) Aluminum Alloy under Variable Temperature

In this work, constant and increasing temperature fatigue interaction effect on fatigue behavior of 2017-T4 aluminum alloy was investigated. Fatigue tests at constant load constant temperature and constant load increasing temperature were performed for five applied stresses which are (350,275,200,17...

Full description

Bibliographic Details
Main Authors: Hussain J. Al-Alkawi, Raad M. Fenjan, Samar K. Abdul-Zahraa
Format: Article
Language:English
Published: Al-Nahrain Journal for Engineering Sciences 2017-08-01
Series:مجلة النهرين للعلوم الهندسية