Dominant factors in MiniCone, CPT and pile correlations: A data‐based approach

Abstract The cone penetration test (CPT) contributes to the design and analysis of piles regarding geometry, installation effect, and pile capacity (shaft and toe resistance). MiniCone, as an alternative to CPT sounding, has been used to carry out field and laboratory investigations by physical mode...

Full description

Bibliographic Details
Main Authors: Seyed Sajad Shirani, Abolfazl Eslami, Amirhossein Ebrahimipour, Moses Karakouzian
Format: Article
Language:English
Published: Wiley 2023-12-01
Series:Deep Underground Science and Engineering
Subjects:
Online Access:https://doi.org/10.1002/dug2.12055