The Duration of the Cycle to Get the P Amplitude on A Discrete Electrocardiogram
The P amplitude value for each cycle has not been carried out even though it is related to indications of atrial hypertrophy. The basic interpretation of the maximum P amplitude under normal conditions is 2.5 small squares on electrocardiogram (ECG) paper which is equivalent to 2.5 mV. Apart from th...