Investigations into the Shear Load-Capacity of Strengthened Reinforced Concrete Structures with Carbon-Reinforced Concrete

As part of the experiments, 4-point-bending tests to investigate the shear capacity of strengthened T-beams were carried out. Thereby, 5 reference beams and 25 T-beams with carbon reinforced concrete strengthening were tested. Two different impregnated carbon grids in various strengthening configura...