FEA-Based Ultrasonic Focusing Method in Anisotropic Media for Phased Array Systems

Traditional ultrasonic imaging methods have a low accuracy in the localization of defects in austenitic welds because the anisotropy and inhomogeneity of the welds cause distortion of the ultrasonic wave propagation paths in anisotropic media. The distribution of the grain orientation in the welds i...