In situ chamber for studying battery failure using high-speed synchrotron radiography

The investigation of lithium-ion battery failures is a major challenge for personnel and equipment due to the associated hazards (thermal reaction, toxic gases and explosions). To perform such experiments safely, a battery abuse-test chamber has been developed and installed at the microtomography be...

Full description

Bibliographic Details
Main Authors: Jonas Pfaff, Matilda Fransson, Ludovic Broche, Mark Buckwell, Donal P. Finegan, Stefan Moser, Sebastian Schopferer, Siegfried Nau, Paul R. Shearing, Alexander Rack
Format: Article
Language:English
Published: International Union of Crystallography 2023-01-01
Series:Journal of Synchrotron Radiation