Continuous demagnetisation assessment for triple redundant nine-phase fault-tolerant permanent magnet machine
In this study, the risk of partial irreversible demagnetisation of a triple redundant, nine-phase fault tolerant machine based on permanent-magnet-assisted synchronous reluctance machine topology has been comprehensively assessed under various faults, including the worst case scenario when the appli...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2019-04-01
|
Series: | The Journal of Engineering |
Subjects: | |
Online Access: | https://digital-library.theiet.org/content/journals/10.1049/joe.2018.8177 |