Multi-Parameter Optimization Design of Axial-Flow Pump Based on Orthogonal Method

The axial-flow pump is a widely used piece of general machinery which consumes large amounts of energy. In this study, an axial-flow pump with the specific speed of 536 is firstly designed and experimentally measured; then, the orthogonal method is employed to conduct the energy performance optimiza...

Full description

Bibliographic Details
Main Authors: Zhenxing Dai, Lei Tan, Bingfu Han, Suyang Han
Format: Article
Language:English
Published: MDPI AG 2022-12-01
Series:Energies
Subjects:
Online Access:https://www.mdpi.com/1996-1073/15/24/9379