Induction Motors Condition Monitoring System with Fault Diagnosis Using a Hybrid Approach
This study develops a condition monitoring system, which includes operating condition monitoring (OCM) and fault diagnosis analysis (FDA). The OCM uses a vibration detection approach based on the ISO 10816-1 and NEMA MG-1 international standards, and the FDA uses a vibration-electrical hybrid approa...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2019-04-01
|
Series: | Energies |
Subjects: | |