Cost-Effective Design Modification of a Sleeve Bearing with Large Bearing Clearance

In 2015, a 45 MW vertical hydropower machine exhibited excessive vibration after refurbishment. Measurements revealed a substantial bearing clearance at the lower generator guide bearing. Consequently, the bearing was unable to generate sufficient opposing force to drive the rotor toward the bearing...

Full description

Bibliographic Details
Main Authors: Gudeta Berhanu Benti, Jan-Olov Aidanpää, Rolf Gustavsson
Format: Article
Language:English
Published: MDPI AG 2024-01-01
Series:Applied Sciences
Subjects:
Online Access:https://www.mdpi.com/2076-3417/14/3/1214