Uncertainty analysis of discharge coefficient of circular crested weirs
Abstract The circular crested weir (CCW) has been introduced as weirs having a high discharge coefficient (Cd). The ratio of flow head to the radius of the crest (H/R) is the most important parameter affecting the Cd, that the $${\text{Cd}} \approx a\left( {H/R} \right)^{b}$$ Cd ≈ a H / R b can math...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
SpringerOpen
2021-01-01
|
Series: | Applied Water Science |
Subjects: | |