Isolating In-Situ Grip and Push Force Distribution from Hand-Handle Contact Pressure with an Industrial Electric Nutrunner

Objectives: Grip force during hand tool operation is the primary contributor to tendon strain and related wrist injuries, whereas push force is a contributor to shoulder injuries. However, both cannot be directly measured using a single measurement instrument. The objective of this research was to d...

Full description

Bibliographic Details
Main Authors: Cederick Landry, Daniel Loewen, Harish Rao, Brendan L. Pinto, Robert Bahensky, Naveen Chandrashekar
Format: Article
Language:English
Published: MDPI AG 2021-12-01
Series:Sensors
Subjects:
Online Access:https://www.mdpi.com/1424-8220/21/23/8120