Isolating In-Situ Grip and Push Force Distribution from Hand-Handle Contact Pressure with an Industrial Electric Nutrunner

Objectives: Grip force during hand tool operation is the primary contributor to tendon strain and related wrist injuries, whereas push force is a contributor to shoulder injuries. However, both cannot be directly measured using a single measurement instrument. The objective of this research was to d...

Full description

Bibliographic Details
Main Authors: Cederick Landry, Daniel Loewen, Harish Rao, Brendan L. Pinto, Robert Bahensky, Naveen Chandrashekar
Format: Article
Language:English
Published: MDPI AG 2021-12-01
Series:Sensors
Subjects:
Online Access:https://www.mdpi.com/1424-8220/21/23/8120
_version_ 1797507142157074432
author Cederick Landry
Daniel Loewen
Harish Rao
Brendan L. Pinto
Robert Bahensky
Naveen Chandrashekar
author_facet Cederick Landry
Daniel Loewen
Harish Rao
Brendan L. Pinto
Robert Bahensky
Naveen Chandrashekar
author_sort Cederick Landry
collection DOAJ
description Objectives: Grip force during hand tool operation is the primary contributor to tendon strain and related wrist injuries, whereas push force is a contributor to shoulder injuries. However, both cannot be directly measured using a single measurement instrument. The objective of this research was to develop and test an algorithm to isolate the grip and push force distributions from in-situ hand-handle pressure measurements and to quantify their distributions among industrial workers using an electric nutrunner. Methods: Experienced automobile assembly line workers used an industrial nutrunner to tighten fasteners at various locations and postures. The pressure applied by the hand on the tool handle was measured dynamically using pressure sensors mounted on the handle. An algorithm was developed to compute the push force applied to the handle of an electric pistol-grip nutrunner based on recorded pressure measurements. An optimization problem was solved to find the contribution of each measured pressure to the actual pushing force of the tool. Finally, the grip force was determined from the difference between the measured pressure and the calculated pushing pressure. Results: The grip force and push force were successfully isolated and there was no correlation between the two forces. The computed grip force increased from low to high fastener locations, whereas the push force significantly increased during overhead fastening. A significant difference across the participants’ computed grip forces was observed. The grip force distribution showed that its contribution to total hand force was larger than other definitions in the literature. Conclusions: The developed algorithm can aid in better understanding the risk of injury associated with different tasks through the notion of grip and push force distribution. This was shown to be important as even workers with considerable power tool experience applied significantly more grip and push force than other participants, all of whom successfully completed each task. Moreover, the fact that both forces were uncorrelated shows the need for extracting them independently.
first_indexed 2024-03-10T04:44:25Z
format Article
id doaj.art-6720afb219b14d95b47f325a321dbf31
institution Directory Open Access Journal
issn 1424-8220
language English
last_indexed 2024-03-10T04:44:25Z
publishDate 2021-12-01
publisher MDPI AG
record_format Article
series Sensors
spelling doaj.art-6720afb219b14d95b47f325a321dbf312023-11-23T03:04:17ZengMDPI AGSensors1424-82202021-12-012123812010.3390/s21238120Isolating In-Situ Grip and Push Force Distribution from Hand-Handle Contact Pressure with an Industrial Electric NutrunnerCederick Landry0Daniel Loewen1Harish Rao2Brendan L. Pinto3Robert Bahensky4Naveen Chandrashekar5Department of Mechanical and Mechatronics Engineering, University of Waterloo, 200 University Avenue West, Waterloo, ON N2L 3G1, CanadaDepartment of Mechanical and Mechatronics Engineering, University of Waterloo, 200 University Avenue West, Waterloo, ON N2L 3G1, CanadaDepartment of Mechanical and Mechatronics Engineering, University of Waterloo, 200 University Avenue West, Waterloo, ON N2L 3G1, CanadaDepartment of Kinesiology, University of Waterloo, 200 University Avenue West, Waterloo, ON N2L 3G1, CanadaDepartment of Mechanical and Mechatronics Engineering, University of Waterloo, 200 University Avenue West, Waterloo, ON N2L 3G1, CanadaDepartment of Mechanical and Mechatronics Engineering, University of Waterloo, 200 University Avenue West, Waterloo, ON N2L 3G1, CanadaObjectives: Grip force during hand tool operation is the primary contributor to tendon strain and related wrist injuries, whereas push force is a contributor to shoulder injuries. However, both cannot be directly measured using a single measurement instrument. The objective of this research was to develop and test an algorithm to isolate the grip and push force distributions from in-situ hand-handle pressure measurements and to quantify their distributions among industrial workers using an electric nutrunner. Methods: Experienced automobile assembly line workers used an industrial nutrunner to tighten fasteners at various locations and postures. The pressure applied by the hand on the tool handle was measured dynamically using pressure sensors mounted on the handle. An algorithm was developed to compute the push force applied to the handle of an electric pistol-grip nutrunner based on recorded pressure measurements. An optimization problem was solved to find the contribution of each measured pressure to the actual pushing force of the tool. Finally, the grip force was determined from the difference between the measured pressure and the calculated pushing pressure. Results: The grip force and push force were successfully isolated and there was no correlation between the two forces. The computed grip force increased from low to high fastener locations, whereas the push force significantly increased during overhead fastening. A significant difference across the participants’ computed grip forces was observed. The grip force distribution showed that its contribution to total hand force was larger than other definitions in the literature. Conclusions: The developed algorithm can aid in better understanding the risk of injury associated with different tasks through the notion of grip and push force distribution. This was shown to be important as even workers with considerable power tool experience applied significantly more grip and push force than other participants, all of whom successfully completed each task. Moreover, the fact that both forces were uncorrelated shows the need for extracting them independently.https://www.mdpi.com/1424-8220/21/23/8120electric nutrunnerinjury preventiongrip forcepistol-grip hand toolpressure mappush force
spellingShingle Cederick Landry
Daniel Loewen
Harish Rao
Brendan L. Pinto
Robert Bahensky
Naveen Chandrashekar
Isolating In-Situ Grip and Push Force Distribution from Hand-Handle Contact Pressure with an Industrial Electric Nutrunner
Sensors
electric nutrunner
injury prevention
grip force
pistol-grip hand tool
pressure map
push force
title Isolating In-Situ Grip and Push Force Distribution from Hand-Handle Contact Pressure with an Industrial Electric Nutrunner
title_full Isolating In-Situ Grip and Push Force Distribution from Hand-Handle Contact Pressure with an Industrial Electric Nutrunner
title_fullStr Isolating In-Situ Grip and Push Force Distribution from Hand-Handle Contact Pressure with an Industrial Electric Nutrunner
title_full_unstemmed Isolating In-Situ Grip and Push Force Distribution from Hand-Handle Contact Pressure with an Industrial Electric Nutrunner
title_short Isolating In-Situ Grip and Push Force Distribution from Hand-Handle Contact Pressure with an Industrial Electric Nutrunner
title_sort isolating in situ grip and push force distribution from hand handle contact pressure with an industrial electric nutrunner
topic electric nutrunner
injury prevention
grip force
pistol-grip hand tool
pressure map
push force
url https://www.mdpi.com/1424-8220/21/23/8120
work_keys_str_mv AT cedericklandry isolatinginsitugripandpushforcedistributionfromhandhandlecontactpressurewithanindustrialelectricnutrunner
AT danielloewen isolatinginsitugripandpushforcedistributionfromhandhandlecontactpressurewithanindustrialelectricnutrunner
AT harishrao isolatinginsitugripandpushforcedistributionfromhandhandlecontactpressurewithanindustrialelectricnutrunner
AT brendanlpinto isolatinginsitugripandpushforcedistributionfromhandhandlecontactpressurewithanindustrialelectricnutrunner
AT robertbahensky isolatinginsitugripandpushforcedistributionfromhandhandlecontactpressurewithanindustrialelectricnutrunner
AT naveenchandrashekar isolatinginsitugripandpushforcedistributionfromhandhandlecontactpressurewithanindustrialelectricnutrunner