Investigation the effect of operating conditions on Te and ne of Argon plasma glow discharge at cathode graphite
In this study, the spectral analysis technique was used to calculate the electron temperature and density of argon gas using the ratio method between the two spectral lines. These parameters were calculated at different pressures (0.375, 0.75, 1.5, 1.875, 2.25 torr) and voltages (240, 250, 260, 270...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
University of Kufa
2019-12-01
|
Series: | Journal of Kufa-Physics |
Subjects: | |