Effects of different stent size selection on pipeline embolization device treatment of intracranial aneurysms

Background: Pipeline embolization device (PED) is becoming increasingly common in therapeutic practice. In idealized model studies, treatment effectiveness may vary with different stent sizes in the same vasculature. The true effect of stent size selection in the clinical setting remains unknown, ho...

Full description

Bibliographic Details
Main Authors: Xin Tong, Mingyang Han, Zhongxue Wu, Xin Feng, Aihua Liu
Format: Article
Language:English
Published: SAGE Publishing 2023-02-01
Series:Therapeutic Advances in Neurological Disorders