Real-time mode of operation data analysis to catch the thread-tip denotes the failure cause of the grid-tie PV central inverter

Abstract The inverter is considered the core of the PV power plant. The inverter’s failure leads to generation loss and decreases plant availability. So, it is required to investigate a clear Root Cause Analysis (RCA) to deduce the failure causes and implement the required corrective action in addit...