Performance of the hygrothermal behavior of the CLT wall using different types of insulation; XPS, PF board and glass wool

The physical input values of buildings were entered into a thermal moisture simulation software called WUFI. The categorized criteria were variables of insulation type, standards of insulation (U-value), climate, and the presence or absence of vapor permeable inside and outside the wall. The simulat...

Full description

Bibliographic Details
Main Authors: Jiwon Yoo, Seong Jin Chang, Sungwoong Yang, Seunghwan Wi, Young Uk Kim, Sumin Kim
Format: Article
Language:English
Published: Elsevier 2021-04-01
Series:Case Studies in Thermal Engineering
Subjects: