Effects of Organic Loading Rate on the Performance of a Pressurized Anaerobic Filter in Two-Phase Anaerobic Digestion

The effect of organic loading rate (OLR) on a pressurized anaerobic filter was studied in a laboratory two-phase anaerobic digestion system. The anaerobic filter was operated successively at two working pressures (9 bar and 1.5 bar). The OLR(COD) for each pressure was increased from 5 to 17.5 kg·m−3...

Full description

Bibliographic Details
Main Authors: Yuling Chen, Benjamin Rößler, Simon Zielonka, Anna-Maria Wonneberger, Andreas Lemmer
Format: Article
Language:English
Published: MDPI AG 2014-02-01
Series:Energies
Subjects: