Derating of Squirrel-Cage Induction Motors Due to High Harmonics in Supply Voltage

This paper presents the results of load capacity calculations for three-phase squirrel-cage induction motors supplied with distorted voltage with rotating harmonics. The calculations were made on the basis of a commonly used model of an induction machine. The difference from many papers is that the...

Full description

Bibliographic Details
Main Author: Tomasz Drabek
Format: Article
Language:English
Published: MDPI AG 2023-09-01
Series:Energies
Subjects:
Online Access:https://www.mdpi.com/1996-1073/16/18/6604