Thermal performance enhancement in a double tube heat exchanger using combination of bubble injection and helical coiled wire insert

In this experimental study, a novel approach combining a helical coiled wire (HCW) turbulator and bubble injection (BI) method has been employed to synergistically improve the heat transfer efficiency of double tube heat exchanger. The thermal-frictional characteristics were evaluated by investigati...