Diagnosis of axial displacement in transformer windings using finite element analysis
Transformer is one of the main equipment in the power system and power quality of the power system mainly depends on the working of the power transformer. Leakage reactance is one of the main parameters of the transformer. The design of the transformer has a significant impact on the leakage reactan...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Mahmut Akyigit
2018-05-01
|
Series: | Journal of Mathematical Sciences and Modelling |
Subjects: | |
Online Access: | https://dergipark.org.tr/tr/download/article-file/482680 |