10-Year Evaluation of the First Root Analogue Implant on Humans, Made Using a CT Scan, CAD/CAM and DMLS
Ten years ago, for the first time in humans, thanks to the DLMS (direct metal laser sintering) technique, we designed, built and inserted an immediate post-extraction custom-made root-analogue implant in Ti-6Al-4v with platform switching. The implant was inserted into the post-extraction socket, res...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2022-03-01
|
Series: | Biomimetics |
Subjects: | |
Online Access: | https://www.mdpi.com/2313-7673/7/1/32 |