Failure analysis of lead‐acid batteries at extreme operating temperatures

Abstract The lead‐acid battery system is designed to perform optimally at ambient temperature (25°C) in terms of capacity and cyclability. However, varying climate zones enforce harsher conditions on automotive lead‐acid batteries. Hence, they aged faster and showed lower performance when operated a...

Full description

Bibliographic Details
Main Authors: Umesh Prasad, Jyoti Prakash, Arunachala Nadar M. Kannan, Venkat Kamavaram, Ganesh K. Arumugam
Format: Article
Language:English
Published: Wiley 2023-07-01
Series:Battery Energy
Subjects:
Online Access:https://doi.org/10.1002/bte2.20230008