Performance-Based Compositive Passive Control Analysis of Multi-Tower Building with Chassis: Optimization of Kelvin-Voigt Dampers

The compositive passive control (CPC) method of “interlayer seismic isolation “plus “shock absorption between adjacent towers” was applied to a multi-tower building (MTB) with a large podium. The interaction between adjacent towers was used to reduce the structural response under seismic action. Bas...

Full description

Bibliographic Details
Main Authors: Shangrong Zhang, Yuchen Hu, Chi Zhang, Shihao Li, Ping Tan
Format: Article
Language:English
Published: MDPI AG 2022-01-01
Series:Buildings
Subjects:
Online Access:https://www.mdpi.com/2075-5309/12/2/137