Characteristics Analysis of Fluid Flow and Heating Rate of a Molten Bath Utilizing a Unified Model in a DC EAF

Herein, a 2D unified model coupling a plasma arc–molten bath–cavity in a direct current electric arc furnace was developed for a characteristic analysis of the fluid flow and heating rate of the molten bath. The ‘local thermodynamic equilibrium–diffusion approximation’ method was employed for the ph...

Full description

Bibliographic Details
Main Authors: Conglin Yao, Zhouhua Jiang, Hongchun Zhu, Tao Pan
Format: Article
Language:English
Published: MDPI AG 2022-02-01
Series:Metals
Subjects:
Online Access:https://www.mdpi.com/2075-4701/12/3/390