Experimental studies into the dependences of the axial lead coolant circulation pump performance on the pump straightening device parameters

The paper presents the results of experimental studies into the dependences of the axial pump performance (delivery rate, head, efficiency) in lead coolant on the parameters of the straightening device (SD) installed downstream of the impeller (the SD inlet flow angle and the number of the SD blades...

Full description

Bibliographic Details
Main Authors: Aleksander V. Beznosov, Aleksander V. Lvov, Pavel A. Bokov, Tatyana A. Bokova, Nikita S. Lukichev
Format: Article
Language:English
Published: National Research Nuclear University (MEPhI) 2019-09-01
Series:Nuclear Energy and Technology
Subjects:
Online Access:https://nucet.pensoft.net/article/39340/download/pdf/