Failure Mechanism of Hot Dip Aluminized Ductile Iron

Using laser scanning confocal microscope, failure process of aluminized ductile iron samples were <i>in-situ</i> observed during three-point bending test, while crack initiation and propagation mechanism were analyzed in the area of coating and matrix. The results show that for hot-dippe...