Radiation damage evolution in pure W and W-Cr-Hf alloy caused by 5 MeV Au ions in a broad range of dpa
Pure W and W-Cr-Hf alloy which are prospective materials for nuclear fusion reactors, such as DEMO, were irradiated at room temperature with 5 MeV Au2+ ions with fluences between 4 × 1014 and 1.3 × 1016 ions.cm−2 to generate various levels of lattice damage from about units up to tens of dpa. The di...
Main Authors: | , , , , , , , , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier
2021-12-01
|
Series: | Nuclear Materials and Energy |
Subjects: | |
Online Access: | http://www.sciencedirect.com/science/article/pii/S2352179121001514 |