Development of a turbine oil contamination diagnosis method using colorimetric analysis of membrane patches
Lubricating oils are used in various machines and devices; however, they degrade during operation because of their usage environment. The causes of lubricating oil contamination are roughly classified into two types: the contamination caused by solid particles and that caused by oil oxidation produc...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
The Japan Society of Mechanical Engineers
2018-08-01
|
Series: | Journal of Advanced Mechanical Design, Systems, and Manufacturing |
Subjects: | |
Online Access: | https://www.jstage.jst.go.jp/article/jamdsm/12/4/12_2018jamdsm0088/_pdf/-char/en |