Corrosion of Copper in Deaerated and Oxygenated 0.1M H2SO4 Solutions under Controlled Conditions of Mass Transfer

The corrosion behavior of copper in deaerated and oxygenated 0.1 H2SO4solutions has been investigated using the rotating cylinder electrode under turbulentflow conditions. Potentiostatic polarization measurements were carried out at differentbulk temperatures of 283, 288, 293 and 298 K and various s...

Full description

Bibliographic Details
Main Authors: Shatha A.Sameh, Issam K.Salih, Sadiq H.Alwash, Asawer AL-Waisty
Format: Article
Language:English
Published: Unviversity of Technology- Iraq 2009-03-01
Series:Engineering and Technology Journal
Subjects:
Online Access:https://etj.uotechnology.edu.iq/article_29316_1b719c0170ac1fa6f7493d6fcb895511.pdf