Rotor Balancing with Considering Measurement Errors

When influence coefficient (IC) method is used in rotor balancing, it is possible that serious errors could be resulted in unbalance determinations due to the contamination of measurements and IC matrix being ill-posed. In this study, the availability of least squares algorithm (LSA) and Tikhonov re...